MIL-O-23678B
4.3.1 First article samples. Unless otherwise specified, as soon as
practicable after the award of a contract or order, the manufacturer shall
submit two systems of each type specified in the contract or order. The
samples shall be representative of the construction, workmanship, components
and materials to be used during the production. When a manufacturer is in
continuous production of these systems from contract to contract, submission
of further first article samples may be waived at the discretion of the
acquiring activity (see 6.2.1c). Approval of the first article samples or the
waiving of the first article inspection does not exclude the requirements of
submitting to the quality conformance inspection. The first article samples
shall be furnished to the Government as directed by the contracting officer
(see 6.2.1c).
4.3.1.1 First article information. Upon completion of the first article
inspection, all the applicable inspection reports and, when applicable,
recommendations and comments pertinent for use in monitoring production will
be forwarded to the cognizant Government activity. One approved system will
be returned to the manufacturer for use in monitoring production. The other
sample may be consumed or destroyed in the first article inspection and shall
not be considered as part of the quantity to be delivered under contract,
4.4 Quality conformance inspection. The sampling and inspection levels
shall conform to MIL-STD-105. The quality conformance inspection shall
consist of the following examinations and tests:
Visual examination
Dimensions
Leakage
Odor
Packaging
4.4.1 Sampling.
4.4.l.l Inspection lot.
4.4.1.1.1 Oxygen system. An inspection lot size shall be expressed in
units of one oxygen system made under essentially the same conditions and from
the same materials and components. The sample unit shall be one oxygen system.
4.4.1 .1.2 Packaging. An
inspection lot size shall be expressed in units of
one fully prepared shipping
containers containing oxygen systems of one type,
fully prepared for delivery
from essentially the same materials and
components. The sample unit
shall be one shipping container, containing
oxygen systems of one type,
fully prepared for delivery with the exception
that it need not be sealed.
4.4.1.2 Sampling for tests and examinations of the oxygen systems. The
sample size, acceptance criteria, tests and examinations required for the
oxygen systems shall be as specified in table I.