MIL-R-17852C(AS)
Shut-off valve
4.6.4
Pressure relief
4.6.5
Proof pressure
4.6.6
High and low temperature
4.6.7
operation
Vibration
4.6.8
Endurance (type I)
4.6.9
Oxygen bomb test
4.6.10
4.3.1 First article samples. Unless otherwise specified, as soon as
practicable, after the award of the contract or order, the manufacturer
shall submit two reducrers. he samples shall be representative of the
construction workmanship, components and materials to be used during
production. When a manufacturer is in continuous production of these
units from contract to contract, submission of further first article
samples on the new contract may be waived at the discretion of the
acquiring activity (see 6.2). Approval of the first article samples or
the waiving of first article inspection does not exclude the requirements
of submitting to the quality conformance inspection. The first article
inspection samples shall be furnished to the Government-as directed by
the contracting officer (see 6.2).
4.3.1.1 First article information. Upon completion of the first
article inspection, all the applicable inspection reports and when
applicable, recommendations and comments pertinent for use in monitoring
production will be forwarded to the cognizant Government activity. One
approved reducer will be returned to the manufacturer for use in monitoring
production. The other sample will be consumed or destroyed in the first
article inspection and will not be considered as part of the quantity to
be delivered under contract.
4.4 Quality conformance inspection. The sampling and inspection
levels shall conform to MIL-STD-105. Quality conformance inspection
shall be as specified in table I.
4.4.1 Sampling.
4.4.1.1 Inspection lot.
4.4.1.1.1 Reducer. An inspection lot size shall be expressed in
units of reducers, made essentially under the same conditions and from
the same materials and components, The sample unit shall be one reducer.
4.4.1.1.2 Packaging. An inspection lot size shall be expressed in
units of one fully prepared shipping container, containing reducers of
one type, fully prepared for delivery, made from essentially the same
materials and components. The sample unit shall be one shipping container,
containing reducers of one type, fully prepared for delivery, with the
exception that it need not be sealed.
4.4.1.2 Sampling for tests and examinations of reducers. The sample
size, acceptance criteria, tests and examinations required for the
reducers shall be as specified in table I.