MIL-DTL-19803G
4.
VERIFICATION
4.1 Classification of inspection. The inspection requirements specified herein are classified
as follows:
a. Qualification inspection. (See 4.2 and 6.3.)
b. First article inspection. (See 4.3.)
c. Conformance inspection. (See 4.4.)
4.2 Qualification inspection. Qualification inspection shall consist of all the examinations
and tests of this specification.
4.2.1 Qualification samples. Qualification samples shall consist of:
a. Two each complete converter assemblies.
b. One each inner vessel complete with all lines and fittings.
c. One each additional sample of the major components specified in 3.6 (excluding the
secondary overpressure safety device).
d. Three each secondary overpressure safety devices (see 3.4.10).
e. A Statement of Certification (with supported test data) from the manufacturer that the
converters conform to the reliability requirements cited in 3.5.16 and 4.6.17.
Samples shall be forwarded to a test facility set forth in the letter of authorization to submit
samples (see 6.3). The samples shall be plainly identified by securely attached durable tags
marked with the following information:
Sample submitted by (name) (date) for qualification inspection in accordance with
the requirements of MIL-DTL-19803 and number under authorization (reference
authorizing letter and number, (see 6.3)).
4.3 First article inspection. First article inspection shall consist of the following
examinations and tests:
Visual examination
Dimensions
Permanent volumetric expansion
Pressure tests
11
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business