MIL-DTL-9370E
4.2.1 Qualification samples. Qualification samples shall consist of two valves of each
MS24350 dash number for which qualification is desired. Samples shall be forwarded to
Commander, Naval Air Systems Command, Code 4.6.8.3, 48110 Shaw Road, Bldg. 2187,
Patuxent River, MD 20670. The samples shall be plainly identified by securely attached durable
tags marked with the following information:
Sample submitted by (name) (date) for qualification inspections
in accordance with the requirements of MIL-DTL-9370E and number
under authorization (reference authorizing letter and number (see 6.3)).
4.3 First article inspection. First article inspection shall consist of the examinations and
tests deemed necessary by the procuring activity.
4.3.1 First article samples. Unless otherwise specified, as soon as practicable after award of
a contract or order, the manufacturer shall forward two valves of each MS24350 dash number as
instructed in the contract or order (see 6.2). The samples shall be representative of the
construction, workmanship, components, and materials to be used during production. When a
contractor is in continuous production of these valves from contract to contract, submission of
further first article samples on the new contract may be waived at the discretion of the procuring
activity. Approval of the first article samples or the waiving of the first article inspection does
not preclude the requirements for the performance of conformance inspection. The first article
samples shall be plainly identified by securely attached durable tags marked with the following
information:
Sample submitted by (name) (date) for first article inspection in
accordance with the requirements of MIL-DTL-9370E under
Contract no. _______________.
4.3.1.1 Disposition of samples. Upon completion of the first article inspection, all the
applicable inspection reports and when applicable, recommendations and comments pertinent for
use in monitoring production, shall be forwarded to the Government quality control
representative. One approved valve shall be returned to the manufacturer for use in monitoring
production. The other valve shall be consumed or destroyed in the first article inspection and
shall not be considered as part of the quantity to be delivered under contract.
4.4 Conformance inspection. Conformance inspection shall consist of performing the
examinations and tests listed in table II.
4.4.1 Sampling.
4.4.1.1 Inspection lot.