MIL-R-85523A(AS)
shall pass the respective requirements of 3.6.1.1, 3.6.2.2.2, 3.6.4.1, and
3.6.4.2. If the regulator design incorporates a relief valve, the regulator
shall be tested as specified in 4.8.4.3 and pass the requirements of 3.6.4.3
after exposure.
3.6.9 Acceleration. The regulator, when tested as specified in 4.8.9, shall operate as required and the outlet pressure shall be in accordance with the
limits specified in Table IV. The regulator shall show no evidence of mechanical or material failure during or after exposure. After exposure, the regulator
shall be tested as specified in 4.8.1.1, 4.8.2.2.2, 4.8.4.1, and 4.8.4.2 and shall pass the respective requirements of 3.6.1.1, 3.6.2.2.2, 3.6.4.1, and
3.6.4.2. If the regulator design incorporates a relief valve, the regulator shall be tested as specified in 4.8.4.3 and pass the requirements of 3.6.4.3 after exposure.
3.6.10 Shock. The regulator, when tested as specified in 4.8.10, shall show no evidence of mechanical or material failure during or after exposure.
After exposure, the regulator shall be tested as specified in 4.8.1.1, 4.8.2.2.2,
4.8.4.1, and 4.8.4.2 and shall pass the respective requirements of 3.6.1.1,
3.6.2.2.2, 3.6.4.1, and 3.6.4.2. If the regulator design incorporates a relief
valve, the regulator shall be tested as specified in 4.8.4.3 and pass the
requirements of 3.6.4.3 after exposure.
3.6.11 Humidity. The regulator, when tested as specified in 4.8.11, shall show no evidence of mechanical or material failure or evidence of corrosion during or after exposure other than superficial staining or tarnish. After exposure, the regulator shall be tested as specified in 4.8.1.1, 4.8.2.2.2,
4.8.4.1, and 4.8.4.2 and shall pass the respective requirements of 3.6.1.1,
3.6.2.2.2, 3.6.4.1, and 3.6.4.2. If the regulator design incorporates a relief
valve, the regulator shall be tested as specified in 4.8.4.3 and pass the
requirements of 3.6.4.3 after exposure.
3.6.12 Salt fog. The regulator, when tested as specified in 4.8.12, shall show no evidence of mechanical or material failure or evidence of corrosion during or after exposure other than superficial staining or tarnish. After exposure, the regulator shall be tested as specified in 4.8.1.1, 4.8.2.2.2,
4.8.4.1, and 4.8.4.2 and shall pass the respective requirements of 3.6.1.1,
3.6.2.2.2, 3.6.4.1, and 3.6.4.2. If the regulator design incorporates a relief
valve, the regulator shall be tested as specified in 4.8.4.3 and pass the
requirements of 3.6.4.3 after exposure.
3.6.13 Dust (fine sand). The regulator, when tested as specified in 4.8.13, shall show no evidence of mechanical or material failure during or after
exposure. After exposure, the regulator shall be tested as specified in 4.8.1.1,
4.8.2.2.2, 4.8.4.1, and 4.8.4.2 and shall pass the respective requirements of
3.6.1.1, 3.6.2.2.2, 3.6.4.1, and 3.6.4.2. If the regulator design incorporates a
relief valve, the regulator shall be tested as specified in 4.8.4.3 and pass the
requirements of 3.6.4.3 after exposure.
3.6.14 Endurance. The regulator, when tested as specified in 4.8.14, shall operate as required and the outlet pressure shall be in accordance with the limits specified in Table II. The regulator shall show no signs of material or mechanical failure during or after simulation. After simulation, the regulator shall be tested as specified in 4.8.1.1, 4.8.2.2.2, 4.8.4.1, and 4.8.4.2 and shall pass the respective requirements of 3.6.1.1, 3.6.2.2.2, 3.6.4.1, and
3.6.4.2. If the regulator design incorporates a relief valve, the regulator shall be tested as specified in 4.8.4.3 and pass the requirements of 3.6.4.3 after exposure.
8
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business