MIL-R-85523A(AS)
TABLE V. Noise level conditions and requirements (see 3.6.3).
1/3 octave band center frequency |
noise level (db) reference 1/ |
reference 2/ |
320 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000 6300 |
95 95 95 95 95 95 95 95 95 95 95 95 95 95 |
30 30 30 30 30 30 30 30 30 30 30 30 30 30 |
1/ Noise level referenced to 2.0 x 10-4 dyne/cm2(0.47 x 10-12W/m2)
2/ Noise level referenced to 2.9 x 10-4 dyne/cm2(1.00 x 10-12W/m2)
TABLE VI. Underwater outlet pressure conditions and requirements (see
3.6.15).
0utlet flowrate (liters/min) |
Water Depth (inches H20) |
Maximum outlet pressure (inches H20) 1/ |
0 and 100 0 and 100 0 and 100 0 and 100 0 and 100 0 and 100 |
12 24 36 48 60 72 |
23 35 47 59 71 83 |
1/ Maximum outlet pressure shall be measured relative to ambient above the water.
TABLE VII. Qualification inspection (see 4.3).
Inspection |
Paragraph |
|
Requirement |
Procedure |