MIL-R-85523A(AS)
TABLE IX. Classification of defects for visual examination of the regulator (see 4.8.1.1).
Critical
1. Material imperfections, foreign matter embedded.
2. Surface unclean, rough misaligned, cracked, nicked or otherwise flawed.
3. Any component missing, malformed, fractured or otherwise damaged.
4. Any component loose or otherwise not securely retained.
5. Incorrectly assembled or improperly positioned components.
6. Any functioning part that works with difficulty.
7. Faulty workmanship or other irregularities.
8. Weight greater than specified.
9. Any component with evidence of grease or oil.
10. Gasket or seal improperly positioned or unevenly compressed.
11. Gaps between surfaces that should be sealed.
12. Evidence of offensive odor or toxic substances.
13. Evidence of the collection of moisture inside the regulator.
14. Evidence of adhesives other than to secure labels.
Minor
201. Marking missing, insufficient, incorrect, illegible or not permanent.
202. Color not as specified.
203. Evidence of excessive use of lubricants.
204. Missing inlet/outlet caps or plugs.