MIL-R-85523A(AS)
TABLE IV. Steady state outlet pressure conditions and requirements
(see 3.6.2.2.2).
Outlet flowrate (liters/min) |
Altitude (x1000 ft) |
Outlet pressure (inches H2O) |
0 75 180 0 75 180 0, 75, 180 0, 75, 180 0, 75, 180 |
0, 30 0, 30 0, 30 34 34 34 36 45 50 |
0.5 to 1.5 0.7 to 2.0 2.0 to 4.5 0.5 to 2.7 0.7 to 3.2 2.0 to 5.7 3.0 to 6.0 13.0 to 16.0 16.0 to 20.0 |
Note:
1. The regulator shall be tested at inlet pressures of 8,30 and 120 psig at each of the above conditions, except as follows:
a. At an inlet pressure of 5 psig, flowrates above 75 lpm shall not be required.
b. At an inlet pressure of 8 psig, flowrates above 100 lpm shall not be required.
2. The conditions and requirements listed above pertain to the following testing.
a. Quality conformance inspection.
b. Quality conformance verification inspection.
c. Environmental exposure inspection.
d. Post-environmental inspection.
3. First article and qualification test conditions and requirements of
4.8.2.2.1 and 3.6.2.2.1 are listed in Table III.
4. Fluctuations in output flow shall not be permitted
22